Technical SheetPerformance Data  |  Coefficient Data | Wiring Diagrams  |  Mounting Diagrams
 
AKA5512EXA Compressor Data Sheet
  Print       Close
 
General Information
       
 
  Compressor Model AKA5512EXA Oil Charge (cc) 512
 
  Bill Of Material AK111AT-004-J7 Oil Type SYNTHETIC
 
  Application Air Conditioning Heat Pump (Evap range) N/A
 
  Evaporating Range -10F to +55F Displacement 1.361
 
  Rating Conditions ASRE/T BTUH 12000
 
  Rating Point +45F Horse Power 1
 
  Refrigerant R-22 Discharge Line Size 0.25
 
  Weight (lbs) 38 Suction Line Size 0.375
 
Electrical Information
 
  Voltage ( 60 Hz ) 115-60-1 Voltage Range ( 60 Hz ) 103.5 - 126.5
 
  Voltage ( 50 Hz ) 100-50-1 Voltage Range ( 50 Hz ) 90 - 110
 
  Watts at Rating Point 1410 RLA 12.5
 
  LRA 62 Motor Type PSC
 
  Start Capacitor Mfd/Volt N/R Motor Torque Normal
 
  Run Capacitor Mfd/Volt 25/370 Minimum Circuit Ampacity N/A
 
  Maximum Continuous Current 16.8 Energy Efficiency Rating 8.51
 
Component Information
 
  Relay Box NONE Integral Relay Box NONE
 
  Capacitor Cabinet Assembly NONE Start Capacitor NONE
 
  Production Run Capacitor NONE ESP Run Capacitor P85E72
 
  Primary Relay NONE Primary Vendor Number NONE
 
  Secondary Relay NONE Secondary Vendor Number NONE
 
  ESP Relay P82969*% Fan Over Load 8300CRAB45
 
  Vendor Over Load CRA2718-135 ESP Over Load P83527
 
  Terminal Cover 70756 Cover Gasket 30629-1
 
  Bale Strap 70723 Over Load Spring NONE
 
  PRV NONE LP Kit LP4
 
  Grommet 70496 Roto Lock Gasket NONE
 
  Sleeve 70459 Roto Lock Valve NONE
 
Drawing Information (click on the drawing number to open the drawing)
 
  Housing Diagram DCAK004 Wiring Diagram 90537-23
 
 
 

 




Corporate Capsule | NACG Home | FAQ | Site Map